Radiator Sizing

Watts/BTU heat output for a room

m

Reading 4 m

m

Reading 3 m

m

Reading 2.4 m

Each adds 10% to heat loss.

Radiators are rated at ΔT50. Lower flow temperatures need a bigger radiator for the same room.

Results

Heat output
2074W
BTU/hr
7076
Room volume28.8 m³
Base rate60 W/m³ (lounge)
Insulation factor×1
External walls2 (×1.2)
Flow temperatureΔT50 — catalogue rating applies as is
MethodRule-of-thumb W/m³ — a first pass, not a heat loss calculation

Suggested Materials

7100 BTU (ΔT50) compact double-panel radiator
Round up at the merchant.
1 pc
TRV (15mm) — thermostatic valve
1 pc
Lockshield valve (15mm)
1 pc
Radiator wall bracket pair
1 pair
15mm copper pipe
6 m
Pipe clip 15mm
8 pc

Estimates use standard UK trade rules of thumb. Always check the bag/spec on the day.