Radiator Sizing
Watts/BTU heat output for a room
Reading 4 m
Reading 3 m
Reading 2.4 m
Each adds 10% to heat loss.
Radiators are rated at ΔT50. Lower flow temperatures need a bigger radiator for the same room.
Results
What to buy — 6 items
Opens at Screwfix, Toolstation and the merchants for your trade. Free account, no card.
Take the whole job with you
A free account gets you the Gaffer for the awkward questions, a checklist for the job with every part on a shopping list, and quotes and invoices you can build and price up. Sending them out is Pro. No card needed.
Create your free accountIndicative design aids — the main figures and where each comes from are listed under "Figures based on" below.
A rule-of-thumb first pass, not a room heat-loss calculation to BS EN 12831-1 or an MCS heat-loss survey.
Figures based on
- Watts per m³ by room (hall 45 to bathroom 80): No source — workshop figure: a fixed estimating assumption, the volume rule of thumb retail BTU calculators use. Not a heat-loss method
- Insulation ×1.3 / ×1.0 / ×0.8 and +10% per external wall: No source — workshop estimate: fixed estimating assumptions; the level and wall count are inputs
- Catalogue output at ΔT50: BS EN 442-2:2014 — radiator outputs are tested and rated at ΔT50. To be confirmed against the published text
- Output at other ΔT: (ΔT ÷ 50)^1.3: Typical — 1.3 is the usual radiator exponent; each model's BS EN 442 test data gives its own. Check the maker's figure for the radiator you pick
- Valves, brackets, 6 m of 15 mm pipe and 8 clips: No source — workshop estimate: fixed estimating assumptions
Indicative design aids. A standard is named with its edition; each is still to be checked against the published text. "Typical" means no standard sets it: check the bag, tin, data sheet or supplier named. "No source" means a workshop estimate: adjust to suit, or, where the box says it is fixed, a fixed estimating assumption.