Radiator Sizing

Watts/BTU heat output for a room

m

Reading 4 m

m

Reading 3 m

m

Reading 2.4 m

Each adds 10% to heat loss.

Radiators are rated at ΔT50. Lower flow temperatures need a bigger radiator for the same room.

Results

Heat output
2074W
BTU/hr
7076
Room volume28.8 m³
Base rate60 W/m³ (lounge)
Insulation factor×1
External walls2 (×1.2)
Flow temperatureΔT50 — catalogue rating applies as is
Method
Rule-of-thumb W/m³ — a first pass, not a heat loss calculation

What to buy — 6 items

7100 BTU (ΔT50) compact double-panel radiator
Round up at the merchant.
1 pc
TRV (15mm) — thermostatic valve
1 pc
Lockshield valve (15mm)
1 pc
Radiator wall bracket pair
1 pair
15mm copper pipe
6 m
Pipe clip 15mm
8 pc

Opens at Screwfix, Toolstation and the merchants for your trade. Free account, no card.

Take the whole job with you

A free account gets you the Gaffer for the awkward questions, a checklist for the job with every part on a shopping list, and quotes and invoices you can build and price up. Sending them out is Pro. No card needed.

Create your free account

Indicative design aids — the main figures and where each comes from are listed under "Figures based on" below.

A rule-of-thumb first pass, not a room heat-loss calculation to BS EN 12831-1 or an MCS heat-loss survey.

Figures based on

  • Watts per m³ by room (hall 45 to bathroom 80): No source — workshop figure: a fixed estimating assumption, the volume rule of thumb retail BTU calculators use. Not a heat-loss method
  • Insulation ×1.3 / ×1.0 / ×0.8 and +10% per external wall: No source — workshop estimate: fixed estimating assumptions; the level and wall count are inputs
  • Catalogue output at ΔT50: BS EN 442-2:2014 — radiator outputs are tested and rated at ΔT50. To be confirmed against the published text
  • Output at other ΔT: (ΔT ÷ 50)^1.3: Typical — 1.3 is the usual radiator exponent; each model's BS EN 442 test data gives its own. Check the maker's figure for the radiator you pick
  • Valves, brackets, 6 m of 15 mm pipe and 8 clips: No source — workshop estimate: fixed estimating assumptions

Indicative design aids. A standard is named with its edition; each is still to be checked against the published text. "Typical" means no standard sets it: check the bag, tin, data sheet or supplier named. "No source" means a workshop estimate: adjust to suit, or, where the box says it is fixed, a fixed estimating assumption.