Stud Wall

Timber + plasterboard + insulation

Stud wall

11 studs, 400 mm centreswall 4000 mm long, 2400 mm high120024003600040080012001600200024002800320036004000Top: board joints (dashed). mmBottom: studs. Not to scale

Mark studs at: 0, 400, 800, 1200, 1600, 2000, 2400, 2800, 3200, 3600, 4000 (last stud, flush with the far end)

m

Reading 4 m

m

Reading 2.4 m

mm

Reading 400 mm

Each deducts a 0.9 × 2.1 m opening from the board and insulation.

Results

Wall area
9.6m²
Boards
8sheet
Studs11 @ 400 mm centres
Plates8 m total
Sides boardedBoth

What to buy — 6 items

CLS 38 × 89mm (2.4m) stud / plate / nogging
Approx 38.4 linear m
16 pc
1200×2400 plasterboard sheet (12.5mm)
8 sheet
38mm drywall screw (box)
Approx 200 screws total
1 box
Jointing tape (90m roll)
1 roll
12.5kg jointing compound
1 tub
100mm acoustic mineral wool slab pack
2 pack

Opens at Screwfix, Toolstation and the merchants for your trade. Free account, no card.

Take the whole job with you

A free account gets you the Gaffer for the awkward questions, a checklist for the job with every part on a shopping list, and quotes and invoices you can build and price up. Sending them out is Pro. No card needed.

Create your free account

Indicative design aids — the main figures and where each comes from are listed under "Figures based on" below.

Figures based on

  • Studs, plates and one noggin row: Geometry — studs at the centres you set plus one, a head and sole plate the length of the wall, one noggin between each pair of studs
  • Timber in 2.4 m pieces: No source — workshop estimate: a fixed estimating assumption (3.0 m and 4.8 m lengths also exist)
  • Plasterboard 1200 × 2400 mm (2.88 m²): Typical — the common UK board size. Check the board you buy
  • Board +10% for waste, 25 screws a board, tape 1 roll per 30 m², compound 0.4 kg/m²: No source — workshop estimate: fixed estimating assumptions. Check the board and compound makers' figures
  • Insulation pack coverage (5.1, 8.4, 2.88, 6.0 m²): Typical — no data sheet retrieved. Check the coverage on the pack
  • Door opening 0.9 × 2.1 m: No source — workshop figure: a fixed estimating assumption; the door count is an input

Indicative design aids. A standard is named with its edition; each is still to be checked against the published text. "Typical" means no standard sets it: check the bag, tin, data sheet or supplier named. "No source" means a workshop estimate: adjust to suit, or, where the box says it is fixed, a fixed estimating assumption.