All calculators

Welding Symbol

Build or read a BS EN ISO 2553 weld symbol in plain English

Welding symbol

Fillet weldon the arrow sideleg 6 mm, throat ≈ 4.2 mmfull length of the jointz6arrow sideother sideJoint not to scale
mm

Reading 6 mm

mm

Reading 0 mm

mm

Intermittent welds are written n × l (e): the number of welds, the length of each, and e, the gap from the end of one weld to the start of the next.

Reading 1

Results

Reads as
z6 fillet
In plain English
Fillet weld on the arrow side, leg length 6mm (throat ≈ 4.2mm), full length of the joint.
Side rule (ISO 2553 system A)
Symbol on the continuous reference line = arrow side; on the dashed identification line = other side. A weld the same on both sides is symmetrical: symbols above and below one continuous line, and the dashed line is left out.
Dimension lettersz leg · a throat · s penetration · n × l (e) intermittent
Contouras welded

Work out wire and gas
Sets up the joint, process and filler. You put the sizes in.

Take the whole job with you

A free account gets you the Gaffer for the awkward questions, a checklist for the job with every part on a shopping list, and quotes and invoices you can build and price up. Sending them out is Pro. No card needed.

Create your free account
Work out wire and gas

Indicative design aids — every figure and its source is listed under "Figures based on" below.

Figures based on

  • Symbols and dimensioning: BS EN ISO 2553:2019 system A
  • Process numbers in the tail: BS EN ISO 4063:2023
  • Symmetrical welds: the dashed identification line is left out: ISO 2553:1984 reference-line clause, note 1: "For symmetrical welds, the dashed line is unnecessary and should be omitted." Hong Kong Buildings Department, Code of Practice for the Structural Use of Steel 2011, Annex C: "For symmetrical welds the identification line (dashed) is omitted." Pages read 13 Nov 2026. The 2019 edition clause was not read (preview of foreword and clauses 1 to 3 only), so it is unconfirmed for 2019
  • Intermittent welds written n × l (e): e is the distance between welds (the gap): ISO 2553 (the intermittent-weld clauses of the 1984 and 2019 editions were not read, so this is unconfirmed for them); the meaning of e is from Hong Kong Buildings Department, Code of Practice for the Structural Use of Steel 2011, Annex C: "l=weld length, e=distance between welds, n=number of welds"; example "z 10 x 100 (150)" is 100 mm long and 150 mm apart. Pages read 13 Nov 2026
  • z is leg length, a is nominal throat thickness (ISO 2553:2019 3.16, 3.17); a = z ÷ √2 for equal legs: ISO 2553:2019 clauses 3.16 and 3.17 (preview read 13 Nov 2026); the division by √2 is our own geometry, not quoted. The arrow drawn into the joint is a drawing choice: Hong Kong Annex C only recommends the arrow line is placed on the side of the joint to be welded

Indicative design aids. "Typical" means no current standard sets it: follow your WPS and the consumable or gas data sheet named. "No source" means a workshop estimate: adjust to suit, or, where the box says it is fixed, a fixed estimating assumption.