Welding Symbol
Build or read a BS EN ISO 2553 weld symbol in plain English
Welding symbol
Reading 6 mm
Reading 0 mm
Intermittent welds are written n × l (e): the number of welds, the length of each, and e, the gap from the end of one weld to the start of the next.
Reading 1
Results
Take the whole job with you
A free account gets you the Gaffer for the awkward questions, a checklist for the job with every part on a shopping list, and quotes and invoices you can build and price up. Sending them out is Pro. No card needed.
Create your free accountIndicative design aids — every figure and its source is listed under "Figures based on" below.
Figures based on
- Symbols and dimensioning: BS EN ISO 2553:2019 system A
- Process numbers in the tail: BS EN ISO 4063:2023
- Symmetrical welds: the dashed identification line is left out: ISO 2553:1984 reference-line clause, note 1: "For symmetrical welds, the dashed line is unnecessary and should be omitted." Hong Kong Buildings Department, Code of Practice for the Structural Use of Steel 2011, Annex C: "For symmetrical welds the identification line (dashed) is omitted." Pages read 13 Nov 2026. The 2019 edition clause was not read (preview of foreword and clauses 1 to 3 only), so it is unconfirmed for 2019
- Intermittent welds written n × l (e): e is the distance between welds (the gap): ISO 2553 (the intermittent-weld clauses of the 1984 and 2019 editions were not read, so this is unconfirmed for them); the meaning of e is from Hong Kong Buildings Department, Code of Practice for the Structural Use of Steel 2011, Annex C: "l=weld length, e=distance between welds, n=number of welds"; example "z 10 x 100 (150)" is 100 mm long and 150 mm apart. Pages read 13 Nov 2026
- z is leg length, a is nominal throat thickness (ISO 2553:2019 3.16, 3.17); a = z ÷ √2 for equal legs: ISO 2553:2019 clauses 3.16 and 3.17 (preview read 13 Nov 2026); the division by √2 is our own geometry, not quoted. The arrow drawn into the joint is a drawing choice: Hong Kong Annex C only recommends the arrow line is placed on the side of the joint to be welded
Indicative design aids. "Typical" means no current standard sets it: follow your WPS and the consumable or gas data sheet named. "No source" means a workshop estimate: adjust to suit, or, where the box says it is fixed, a fixed estimating assumption.